• <code id="qad0s"></code>
  • <th id="qad0s"><video id="qad0s"></video></th>

  • <pre id="qad0s"></pre>
    <big id="qad0s"><em id="qad0s"><kbd id="qad0s"></kbd></em></big>

    產品中心

    人血漿谷胱甘肽過氧化物酶(GPX3)酶聯免疫吸附檢測試劑盒
    ELK3444
    規格: 價格:
    48T ¥1960.00
    96T ¥2800.00

    Overview 文獻

    Product name: Human GPX3(Glutathione Peroxidase 3, Plasma) ELISA Kit
    Reactivity: Human
    Alternative Names: GSHPX3; GPx-P; GSHPx-P; GPXP; Plasma glutathione peroxidase; Extracellular glutathione peroxidase
    Assay Type: Sandwich
    Sensitivity: 0.62 ng/mL
    Standard: 100 ng/mL
    Detection Range: 1.57-100 ng/mL
    Sample Type: Serum, plasma, breast milk and other biological fluids
    Assay Length: 3.5h
    Research Area: Enzyme & Kinase;
    Uniprot ID: P22352
    Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human GPX3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human GPX3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human GPX3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human GPX3 in the samples is then determined by comparing the OD of the samples to the standard curve.

    標準曲線

    Concentration (ng/mL) OD Corrected OD
    100.00 1.961 1.880
    50.00 1.593 1.512
    25.00 1.127 1.046
    12.50 0.869 0.788
    6.25 0.539 0.458
    3.13 0.342 0.261
    1.57 0.190 0.109
    0.00 0.081 0.000

    精密度

    Intra-assay Precision (Precision within an assay):CV%<8%

    Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

    Inter-assay Precision (Precision between assays):CV%<10%

    Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

    回收率

    Matrices listed below were spiked with certain level of recombinant GPX3 and the recovery rates were calculated by comparing the measured value to the expected amount of GPX3 in samples.
    Matrix Recovery range Average
    serum(n=5) 82-98% 90%
    EDTA plasma(n=5) 80-97% 88%
    Heparin plasma(n=5) 82-94% 88%

    線性

    The linearity of the kit was assayed by testing samples spiked with appropriate concentration of GPX3 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
    Matrix 1:2 1:4 1:8 1:16
    serum(n=5) 95-102% 93-101% 97-105% 95-103%
    EDTA plasma(n=5) 88-97% 86-92% 81-93% 89-105%
    Heparin plasma(n=5) 85-94% 79-96% 92-101% 83-90%
    關閉

    在線咨詢

    Online consultation

    • 在線咨詢
    • 技術支持

    關注微信公眾號

    微信掃一掃立即咨詢

    微信掃一掃立即咨詢

    關閉
    无码一区在线观看视频,亚洲v欧美v日韩v国产,91偷拍亚洲精品,一级a性生活久久无码