• <code id="qad0s"></code>
  • <th id="qad0s"><video id="qad0s"></video></th>

  • <pre id="qad0s"></pre>
    <big id="qad0s"><em id="qad0s"><kbd id="qad0s"></kbd></em></big>

    產品中心

    大鼠白介素6(IL6)酶聯免疫吸附檢測試劑盒
    ELK1158
    規格: 價格:
    48T ¥1680.00
    96T ¥2400.00

    Overview 文獻

    Product name: Rat IL6(Interleukin 6) ELISA Kit
    Reactivity: Rat
    Alternative Names: IL-6;MGI2-A; MGI2A; HGF; BSF2; HSF; IFNB2; B-Cell Stimulatory Factor-2; Hybridoma/Plasmacytoma Growth Factor; Hepatocyte Stimulating Factor; Cytotoxic T-Cell Differentiation Factor
    Assay Type: Sandwich
    Sensitivity: 3.3 pg/mL
    Standard: 500 pg/mL
    Detection Range: 7.82-500 pg/mL
    Sample Type: serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
    Assay Length: 3.5h
    Research Area: Cytokine;Tumor immunity;Infection immunity;Cardiovascular biology;
    Uniprot ID: P20607
    Test principle: The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Rat IL6. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Rat IL6. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Rat IL6, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Rat IL6 in the samples is then determined by comparing the OD of the samples to the standard curve.

    標準曲線

    Concentration (pg/mL) OD Corrected OD
    500.00 2.153 2.068
    250.00 1.628 1.543
    125.00 1.243 1.158
    62.50 0.948 0.863
    31.25 0.507 0.422
    15.63 0.357 0.272
    7.82 0.215 0.130
    0.00 0.085 0.000

    精密度

    Intra-assay Precision (Precision within an assay):CV%<8%

    Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

    Inter-assay Precision (Precision between assays):CV%<10%

    Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

    回收率

    Matrices listed below were spiked with certain level of recombinant IL6 and the recovery rates were calculated by comparing the measured value to the expected amount of IL6 in samples.
    Matrix Recovery range Average
    serum(n=5) 81-95% 88%
    EDTA plasma(n=5) 87-99% 93%
    Heparin plasma(n=5) 87-99% 93%

    線性

    The linearity of the kit was assayed by testing samples spiked with appropriate concentration of IL6 and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
    Matrix 1:2 1:4 1:8 1:16
    serum(n=5) 89-97% 85-94% 79-96% 85-99%
    EDTA plasma(n=5) 86-98% 91-103% 85-97% 87-96%
    Heparin plasma(n=5) 87-95% 85-97% 89-101% 85-97%
    關閉

    在線咨詢

    Online consultation

    • 在線咨詢
    • 技術支持

    關注微信公眾號

    微信掃一掃立即咨詢

    微信掃一掃立即咨詢

    關閉
    无码一区在线观看视频,亚洲v欧美v日韩v国产,91偷拍亚洲精品,一级a性生活久久无码